Is it possible that there is no number on the instrument dial?
A user reported that the thermal resistance "because the instrument number of the dial is printed under the dial, and the handwriting is very small, it is difficult to read clearly", because "all new meters must be calibrated and graded before use, so the indicator on the dial The serial number is very important, and it is difficult to distinguish it if it is not clear, registration and reference."
A wholly foreign-owned company has ordered a large number of pressure gauges in recent years, and no gauge number is required to be printed on the dial. At the beginning of 2003, it was suddenly proposed that the dials of all pressure gauges purchased in the future must have an instrument number, and even pressure gauges that are about to ignite must not have an instrument number, otherwise they will be rejected.
If there is no gauge number on the dial of the pressure gauge, is it a quality problem? Can it be used as a reason for rejection?
This must be considered and analyzed from the following three aspects:
1. In the national standard for stainless steel pressure gauges (GB/T 1226-2001), Article 8.1 "Marks" stipulates that the thermal resistance on the instrument change plate should generally indicate:
a, the name or trademark of the manufacturer
b. Instrument name
c. Pressure unit
d. Accuracy level
e. Manufacturing year and month and instrument number
2. In the Pressure Gauge Appraisal Regulations (JJC 52-1999), one of the clauses that should be filled in the pressure gauge verification record in the appendix is the instrument number column.
3. The pressure gauge is a measuring instrument. It should be verified every six months or a year according to the regulations. If there is no serial number on the dial of the instrument, the identification record and registration cannot be carried out.