+86-571-88550927

Oil filled pressure gauge

Jun 02, 2022

The oil filling of the pressure gauge can only be carried out under the condition of special equipment.

The main purpose of filling the pressure gauge with oil is to reduce the buffering of the pointer to the zero position when the relative pressure changes greatly, which can effectively ensure the sensitivity of the pressure gauge. It mainly includes two kinds of glycerin and silicone oil. Glycerin: mainly for anti-seismic effect; silicone oil: also for anti-vibration effect, but silicone oil is more resistant to low temperature than glycerin. If the outdoor temperature is -20 ℃, glycerin will crystallize, but silicone oil can also make the instrument work normally.

3.23

According to JJG52-1999, only the oxygen pressure gauge and the hydrogen pressure gauge need to be filled with oil, but in actual use, many customers also require no oil for fluorine gas and high-purity rare gas.

2.9

Both glycerin and silicone oil can be used, but which oil to choose should be considered;

1. Thermal expansion coefficient, the smaller the coefficient, the better. (temperature effect)

2. Use occasions. Neither of these oils can be used in the food industry, as the oil will contaminate the food if the diaphragm is damaged. It is also not recommended where strong oxidizing agents are measured, which could cause an explosion.


Send Inquiry