Precautions for the use and installation of integrated temperature transmitter
1. The installation environment of the integrated temperature transmitter must be within -20-+70℃. When the ambient temperature is too high, the signal converter and display module can be installed separately from the thermal resistance or thermocouple. It must be equipped with a dedicated explosion-proof box for separate installation of the transmitter. Please pay attention to the explosion-proof signs and protection grades when used in explosion-dangerous places.
2. Before powering up, please check the positive and negative polarity of the power supply carefully, and you can't connect it wrong, otherwise it may cause unknowable consequences.
3. The temperature transmitter needs to be calibrated after six months of use.
4. The signal converter module is potted and cured with epoxy resin to enhance its shock-proof performance, and is moisture-proof, anti-corrosion, and moisture-proof.
5. High precision, low power consumption, wide operating environment temperature range, stable and reliable work.
6. It has a wide range of applications. It can not only form an integrated field installation structure with thermocouples and thermal resistances, but also can be used as a functional module to be installed in testing equipment and instrument panels.
7. The integrated temperature transmitter can adjust the display direction of the transmitter according to the actual needs of the user, and display the medium temperature measured by the transmitter, the change of the sensor value, the output current and the percentage.
8. It is installed in the junction box of thermocouple and thermal resistance on site, and directly outputs 4-20mA and 0-10mA output signals. This not only saves the cost of expensive compensation wires, but also improves the anti-interference ability in the process of long-distance signal transmission.
9. The integrated temperature transmitter can communicate with the host computer through the HART modem or with the handheld device and the PC for remote information management, configuration, variable monitoring, calibration and maintenance functions of the transmitter's model, index number and range .
10. It adopts silicon rubber or epoxy resin sealing structure, so it is resistant to vibration and humidity, and is suitable for installation and use in harsh on-site environments. The thermocouple transmitter has the function of automatic cold junction temperature compensation.