National Standards For Pressure Gauge Calibration And Calibration Cycles

May 19, 2026

National standards for pressure gauge calibration and calibration cycles

1. Not all pressure gauges require mandatory calibration. There are three types of 11-category pressure gauges that require mandatory calibration, including pressure gauges for safety protection (category 7), wind pressure gauges (category 1), oxygen meters (category 2), and oxygen meters for medical and health care (category 1).
2. The calibration cycle of the forced inspection pressure gauge generally refers to the "Calibration Regulations for Spring Tube Type General Pressure Gauges, Pressure Vacuum Gauges and Vacuum Gauges" (JJG52-1999). This regulation stipulates that the calibration cycle generally does not exceed half a year, and the calibration cycle cannot be extended, but it can be shortened.
3. For non-compulsory inspection pressure gauges, the user unit shall conduct regular inspections on its own or submit them to other metrology verification institutions for verification, and the metrology administrative department of the people's government at or above the county level shall conduct supervision and inspection.
4. New regulations on pressure gauge calibration and calibration cycles - 20231016.doc: This document discusses issues related to pressure gauge calibration from the perspective of production safety law enforcement supervision, including the scope of mandatory calibration, the calibration cycle of pressure gauges under mandatory inspection, and the calibration of pressure gauges without mandatory inspection.
5. Relevant regulations on pressure gauge calibration and calibration cycles: The article also focuses on pressure gauge calibration and calibration cycles. It is analyzed based on laws, regulations, rules and normative documents, and is complementary to the content of the above documents.

How To Prevent Corrosion On The Stainless Steel Pressure Gauge Casing?Four Classifications Of Electric Contact Pressure Gauges And Wiring Arrangement Methods

1. National standards for pressure gauge calibration cycles vary depending on the type and situation of the pressure gauge: the calibration cycle for general pressure gauges generally does not exceed half a year; the calibration cycle for precision pressure gauges is up to one year.
2. Calibration cycles of pressure gauges with different accuracy levels (according to GB/T1226-2001): The calibration cycle of pressure gauges with pressure levels of 0.1 and 0.2 shall not exceed two years; the calibration cycle of pressure gauges with pressure levels of 0.5, 1.0 and 1.6 shall not exceed four years; the calibration cycle of pressure gauges with pressure levels of 2.5 shall not exceed six years. However, the above regulations only apply to pressure gauges under normal use conditions.
3. Calibration cycles of different types of pressure gauges: Type A is a compulsory calibration pressure gauge related to production safety and environmental monitoring. According to JJG52-1999 calibration regulations, the calibration cycle is half a year, and can only be less than half a year; if the industrial and mining conditions are harsh, the calibration cycle must be shorter; in principle, Class B should not exceed the provisions of the calibration regulations (generally not more than half a year); Class C can determine the calibration cycle according to the characteristics of the enterprise, but there should be a method to determine the calibration cycle.
4. How long is the calibration cycle of a pressure gauge?: This link introduces that the cycle of general pressure gauges such as spring tube type is half a year, and the maximum cycle of precision pressure gauges is one year. It also mentions the calibration cycle calculation and other content.
5. How often should a pressure gauge be inspected_How often is a pressure gauge verification cycle: This link explains the verification cycles of pressure gauges of different accuracy levels based on GB/T1226-2001, as well as the difference between forced inspection and non-forced inspection pressure gauges.
6. How long is the calibration period for pressure gauges: The webpage mentions that the calibration period for general pressure gauges should generally not exceed half a year, and the longest for precision pressure gauges is one year.
7. What are the relevant national regulations on the calibration cycle of pressure gauges?: This article introduces the calibration cycle regulations of pressure gauges of different categories (A, B, and C).

Send Inquiry