About The Important Role Of Electric Contact Pressure Gauge in Water Pump Control System

Sep 22, 2022

You must not know that the electric contact pressure gauge plays an important role in the use of the electric contact pressure gauge. Of course, in the water pump control system, the electric contact pressure gauge plays a vital part. Why do you say that? Let me take you to find out.


The electric contact pressure gauge is similar to the ordinary pressure gauge. It is based on the spring tube in the measurement system, which forces the end of the spring tube to produce corresponding elastic deformation and displacement under the pressure of the measured medium. Pre-enlarged, the indication on the fixed gear (together with the contacts) will indicate the measured value on the dial. The difference is that there are auxiliary contacts inside the electric contact pressure gauge, which are usually used together with corresponding electrical devices (such as relays and inverters). The circuit in the signal system can be disconnected or connected, and the purpose of automatic control and sending of signals (alarms) to various gas and liquid media of the measured (controlled) pressure is realized through the instrument.

2.17

Electric contact pressure gauges are widely used in petroleum, chemical, metallurgy, power stations, machinery and other industrial sectors, or in mechanical and electrical equipment to measure the pressure of various fluid media without explosion hazards. The supplementary pressure pump and the voltage stabilizer pump in the system all use the electric contact pressure gauge to control the start and stop of the pump, so as to keep the pressure in the pipe network stable within the required range.


Under normal circumstances, the electric contact pressure gauge is connected to the water outlet pipe at the back end of the pump through the buffer pipe, connected to the pressure signal control line, and connected to the secondary control circuit of the pump. Theoretically, when the control system is in the automatic state, when the pressure in the pipe reaches the pressure indicated by the low pointer, the water pump control system obtains the signal to start the pump and the pump starts; when the pressure in the pipe rises to the pressure indicated by the high pointer, the water pump control system obtains the signal to stop the pump , the pump stops.


During the actual commissioning, it was found that the pipe network of the hotel system is large, and the power, lift and flow of the pump used in the fire protection are large. Even if the buffer pipe is added, the large fluctuation of the pressure in the pipe when the pump is started and stopped cannot be avoided, which directly leads to The pointer of the pressure gauge shakes greatly and frequently, and the pump control system keeps receiving the signal of starting and stopping the pump, and the pump will start and stop frequently, which cannot achieve a good voltage stabilization effect, and it is easy to damage the pressure gauge. It may affect the service life of the pump or even directly lead to the failure of the pump.