Product introduction
It is used to measure the pressure of non-crystalline, non-solidified explosive mixtures or various non-explosive media in explosive dangerous places. Explosion-proof electrical contact pressure gauges are in accordance with GB3836.183 "General requirements for explosion-proof electrical equipment for explosive environments" and GB3836 .283 "Explosion-proof electrical equipment for explosive atmospheres and explosion-proof electrical equipment "d"" relevant regulations and related standards are designed, and the drawings and technical documents approved by the inspection agency are used for manufacturing.
Product Introduction

It is used to measure the pressure of non-crystalline, non-solidified explosive mixtures or various non-explosive media in explosive dangerous places.
The explosion-proof electrical contact pressure gauge is designed in accordance with the relevant regulations and relevant standards of GB3836.1 83 "General Requirements for Explosion-proof Electrical Equipment for Explosive Environments" and GB3836.2 83 "Explosion-proof Electrical Equipment for Explosive Environments and Explosion-proof Electrical Equipment "d"" , And manufactured by the drawings and technical documents approved by the inspection agency.
The explosion-proof category of the instrument is Class II explosion-proof type B Class T4 group, and its mark is Exd II BT4.
The instrument is suitable for measuring the pressure of non-crystalline, non-solidified explosive mixtures or various non-explosive media in explosive places.
The instrument is used in conjunction with electrical devices (such as relays and contactors, etc.) that have corresponding explosion-proof performance or take corresponding safety measures to achieve automatic control and signal (alarm) purposes for the controlled system.
Specifications
· Accuracy level: 1.5
· Scale range: 0~0.16; 0~0.25; 0~0.4; 0~0.6; 0~1; 0~1.6; 0~2.5; 0~4; 0~6; 0~10; 0~16; 0 ~25; 0~40; 0~60; -0.1~0.06; -0.1~0.15;
-0.1~0.3; -0.1~0.5; -0.1~0.9; -0.1~1.5; -0.1~2.4Mpa
· Control mode: upper and lower limit slow travel contact switch
· Working voltage: DC 220V or AC 380V;
· Contact power: 10VA
· Working position: vertical installation
· Operating environment conditions: -10~50℃, relative humidity is not more than 80%, and explosive mixture should be under ⅡB class T4 group, working vibration and the sharp pulsation of the measured medium should have no influence on the reliable operation of the instrument contact.
· Temperature influence: the indicated value is not more than 0.4%/10°C, and the set point is not more than 0.6%/10°C (the operating temperature deviates from 20±5°C).
· Dielectric strength: 50Hz sinusoidal alternating current 2000V lasts for one minute