How to use and test the pressure gauge?
The single column working resistance detector is an instrument for detecting the setting force (working resistance) of a single hydraulic prop. It has the advantages of small size, light weight, portable, convenient operation, etc., especially the reasonable design of the process structure. It is incomparable among similar products and is favored by operators. This product has low cost and is suitable for daily carrying inspection of high-end general mining face batch equipment. It is the daily inspection of the support quality of single hydraulic props to ensure efficient and safe production. Ideal product.
The single-column working resistance tester is mainly composed of a U-shaped card, a measuring body, a thimble and a pressure rod. When using it, the U-shaped card is first set on the three-purpose valve, and then the measuring body port is inserted into the U-shaped card. Rotate the U-shaped card to make the measuring body port and the three-way valve fit together, and then rotate the pressure rod slightly harder and press down the pressure rod. At this time, the thimble just opens the spherical one-way valve in the three-way valve to make the liquid in the pillar The pressure is equivalently transferred into the pressure gauge along the periphery of the thimble in the measuring body, and the setting force (working resistance) value of the pillar can be read from the gauge head.
2. Main technical indicators:.
Pressure gauge range: -0.1~0-60Mpa.
Accuracy: 2.5%F/S (1.6%F/S).
Display mode: mechanical.
Use precautions and maintenance.
Before use, check whether the rubber gasket in the measuring body port is flat. If it is not placed smoothly, it may leak out from the measuring body port.
The leaking liquid from the rear end of the thimble is damaged and deformed. At this time, the pressing rod can be removed, the thimble can be pulled out from the tail, and the "O" seal can be replaced.
The meter head can be used to tighten the meter head with a 6# small torx wrench.
If there is no pressure display on the meter head, there are several possibilities: one is that the pressure gauge is over-tightened and the sealing ring is deformed and blocked, preventing the transmission of liquid pressure. At this time, the meter head and the protective cover can be removed to replace the sealing ring, and the other It may be that the thimble is not long enough, or the thimble does not fit well with the three-way valve, and the three-way valve cannot be opened. Please contact us to replace the thimble. The insufficient thimble length is caused by the different specifications of the three-way valve. Therefore, when ordering* It is good to explain the specifications of the three-purpose valve in advance (such as whether it is an anti-flying safety three-purpose valve, etc.). Another possibility is that the muzzle flat washer is too tightly matched with the thimble. You can repeatedly press the pressure rod and the differential pressure gauge until the pressure is reached. The gauge shows the pressure.
Do not use too much force when rotating the pressure rod (just a little force), so as not to damage the pressure rod.
The needle of the meter head does not return to the zero position, and it does not affect the measurement accuracy, which is mainly caused by measuring the fluid tension in the body.
The thimble should be removed regularly and wiped with butter to prevent corrosion.
3. Main technical indicators:.
Range: 0-40/60Mpa.
Accuracy: 2.5%F/S.
display mode: micro-table type.