Selection Of Installation Pressure Extraction Point

Jan 15, 2022

1. When opening holes on pressure pipes, mechanical opening method (electric drill or hand drill) must be adopted. Note: Air cutting method can be used to open holes on air pressure pipes, and the hole mouth should be polished with round file after cutting. The end of the pressure source part shall not exceed the inner wall of the equipment or pipe.

2. If there is a protruding object (such as a temperature measuring element) in the pipe, the pressure source component should be installed in front of it.

3. The installation position of the pressure source component should be selected in the stable place of the medium stream, and avoid the area where the pipeline is bent, bifurcated or eddy current is formed by the stream.

4. When the pressure must be taken near the regulating valve, if the pressure inlet is in front of it, the distance from the valve should not be less than 2 times the pipe diameter; If the pressure outlet is behind, the distance from the valve should not be less than 3 times the pipe diameter.

5. When measuring the pressure of turbid medium such as dust, solid particles or sediment, the source part should be installed upward. The horizontal process pipe should be installed at an acute Angle.

6. When measuring the pressure of liquids, vapors and coagulable gases at temperatures above 60 ° C, the pressure gauge installed in place shall have a ring or U-shaped condensation bend as the source component.

7. When the pressure source parts are installed on the horizontal and inclined process pipelines, the position of the pressure inlet should meet the following requirements:

 Measure the gas pressure on the top part of the process pipe.

 Measure the liquid pressure at an Angle of 0 to 45 degrees between the lower part of the process pipe and the horizontal center line of the process pipe.

 When measuring the steam pressure, keep the upper and lower parts of the process pipe at an Angle of 0 to 45 degrees from the horizontal center line of the process pipe.