Two Details That Temperature Sensors Are Easy To Ignore

Jun 29, 2021

Two details that temperature sensors are easy to ignore

The principle and installation of the temperature sensor have been said a lot, and most people already know it well, but there are two details that are easy to overlook in the process of using the temperature sensor. One is its working temperature, and the other is its insertion depth.

n202106291403442706594

  The normal operation of the temperature sensor element is to meet its operating conditions, one of which is its operating current. Because the temperature sensor has a resistance value, when the current flows through the temperature sensor element, there will be power loss and heat generation, so in order to Reduce the temperature measurement error caused by the heating of the sensor itself, so it is necessary to reduce the heating of the sensor as much as possible under the conditions of normal operation of the sensor. This is why the temperature sensor should be used under constant low current conditions. So for example, the normal working current of platinum thermal resistance is 5MA, but our recommended working current is 1MA. The reason is to reduce the measurement error caused by the self-heating of the temperature sensor element. When the current is constant, the output will have a linear relationship between temperature and electric potential.


   The insertion depth of the temperature sensor is also a problem that is easy to ignore. Some customers require that the insertion depth is short but the diameter is relatively large. This is unreasonable, especially in the case of high temperature, which is not advisable. Theoretically speaking, the insertion of the temperature sensor The depth can generally be determined according to actual needs. But the minimum insertion depth should not be less than 8-10 times the diameter of the temperature sensor protection tube. Only in this way can the temperature sensor performance be stable.


   Knowing the working current and insertion depth of the temperature sensor is necessary for us to select and use the temperature sensor. If you ignore these two details, it is easy to cause unstable performance or even damage to the temperature sensor.