+86-571-88550927

Contact Us

  • Factory: No.90 xinxin Rd, Fengdu industrial zone, Hangzhou, China.311115.
  • Office: Rm 707, 3# haloplaza, Liangzhu, Yuhang Dist, Hangzhou, China.
  • Jeffkf1502@163.com
  • Tel: +86-0571-88550927

  • Fax: +86-0571- 88550920

  • Wechat / Whatsapp: + 86 18758159121

What Problems Should Be Paid Attention To When Using Diaphragm Pressure Gauges?

Jan 03, 2022

What problems should be paid attention to when using diaphragm pressure gauges?

The diaphragm pressure gauge is composed of various ordinary pressure gauges and diaphragm isolators of different structures to form a closed system, filled with sealing liquid. When the pressure of the measured medium acts on the diaphragm, the diaphragm deforms and compresses the sealing liquid in the closed system. Due to the inherent nature of the sealing fluid, the elastic element in the pressure gauge produces corresponding elastic deformation. When the stiffness of the diaphragm is small enough, the pressure indicated by the pressure gauge is equal to the pressure value of the measured medium.

3.8


The Y-100B-F/Z/ML diaphragm pressure gauge is composed of a diaphragm isolator and a general-purpose pressure gauge. Its sealing diaphragm, when the pressure P of the measured medium acts on the diaphragm, it deforms, compresses the working fluid filled in the system, and makes the working fluid form a △P equivalent to P, with the help of work. The conduction of the liquid causes the free end of the elastic element (spring tube) in the pressure meter to produce a corresponding elastic deformation and displacement, and then display the measured pressure value according to the working principle of the corresponding pressure meter.


  What problems should be paid attention to when using a diaphragm pressure gauge?


  Because the diaphragm pressure gauge system is filled with sealing liquid as the pressure transmission medium, the temperature influence of the diaphragm pressure gauge is related to the linear expansion coefficient of the sealing liquid, the stiffness of the diaphragm and the temperature of the pressure part. When the operating temperature of the instrument deviates from the specified value [such as (20±5)°C], the impact on the low-range pressure gauge is obvious. Generally, the temperature error of the pressure receiving part is specified to be no more than 1.0%/℃, so the temperature influence value of the diaphragm pressure gauge is the sum of the temperature influence value of the ordinary pressure gauge and the pressure part temperature influence value of the diaphragm isolator. This is necessary in use Attention.


Pay attention to the influence of liquid level static pressure on the diaphragm pressure gauge during use. For diaphragm pressure gauges with flexible connecting pipes, when the pressure part of the diaphragm and the installation position of the ordinary pressure gauge are not at the same height, there will be a difference in liquid column and affect the measurement results. , It needs more attention when measuring accurately.


   The main purpose of the diaphragm pressure gauge is to prevent corrosion, so it can be ensured by selecting the appropriate diaphragm material and the material of the diaphragm, flange and sealing gasket in contact with the measuring medium.


Send Inquiry