Would You Use An Electromagnetic Flowmeter?

Jun 28, 2022

Electromagnetic flowmeter is a kind of speed-type instrument with the advantages of high precision, good repeatability, and convenient installation and use. It is suitable for clean or basically clean pipeline pressure in petroleum, chemical, city gas, metallurgy, mining and other industries relative to constant gas and single-phase gas, such as natural gas, propane, butane, ethylene, nitrogen, air, etc. Electromagnetic flowmeters use turbines for measurement. It first converts the flow rate into the rotational speed of the turbine, and then converts the rotational speed into an electrical signal proportional to the flow rate. This flowmeter is used to detect instantaneous flow and total accumulated flow, and its output signal is frequency, which is easy to digitize. The induction coil is fixed on the housing together with the ** magnet. When the ferromagnetic turbine blade passes the magnet, the reluctance of the magnetic circuit changes, thereby generating an induced signal. The signal is amplified and shaped by the amplifier and sent to the counter or frequency meter to display the total accumulated flow. At the same time, the pulse frequency is converted from frequency to voltage to indicate the instantaneous flow. The speed of the impeller is proportional to the flow, and the number of revolutions of the impeller is proportional to the total flow. The output of the electromagnetic flowmeter is a frequency modulated signal, which not only improves the anti-interference of the detection circuit, but also simplifies the flow detection system. Its turndown ratio can reach 10:1, and the accuracy is within ±0.2%. The time constant of electromagnetic flowmeters with low inertia and small size can reach 0.01 seconds.

5.31A

The working principle of the electromagnetic flowmeter: the measured gas entering the instrument is rectified and accelerated under the action of the special structure B-type rectifier. Since the turbine blades and the fluid flow at a certain angle, a rotational torque is generated under the action of the fluid. Under certain conditions, The angle at which the turbine rotates is proportional to the fluid volume. The rotation of the turbine drives the mechanical counter through the worm, the magnetic connector and the deceleration system to display the working condition volume capacity of the measured gas.

Electromagnetic flowmeter features:

1. The B-type rectifier with its own unique structure has low requirements for the straight pipe sections before and after the instrument (front>=3DN, rear>=1DN);

2. Adopt self-lubricating roller bearings, easy to use and maintain;

3. Using mechanical display, no power supply, no flameproof requirements;

4. Short-time overload 1.2Qmax, no damage to the instrument;

5. Small pressure loss and strong anti-interference ability;

Proper use of electromagnetic flowmeter: The operation of the flowmeter must be checked frequently, maintenance work should be done, and problems should be eliminated in time.

1. Before the electromagnetic flowmeter is put into operation, it is necessary to set the meter coefficient, check it carefully, and make sure that the connection of the flowmeter is correct and the grounding is good before power transmission.

2. Regularly clean, check and recalibrate the flowmeter. For flowmeters equipped with lubricating oil or cleaning fluid injection ports, lubricating oil or cleaning fluid should be injected regularly according to the requirements of the manual to maintain the good operation of the impeller.

3. Monitor the status of the display meter, evaluate the display meter reading, and check in time if there is any abnormality.

4. Keep the filter unblocked. The filter is blocked by impurities, which can be judged from the increase in the difference between the pressure gauge readings at its inlet and outlet. If the blockage occurs, remove it in time, otherwise, the flow will be seriously reduced.

5. For large-flow trade settlement measurement, in order to ensure the accuracy of the flowmeter, the flowmeter must be checked frequently. The site should be equipped with on-line calibration equipment, or equipped with a mobile calibration device. Although the one-time investment is large, it is worthwhile considering the long-term economic benefits.

5.31B

Conditions of Use:

1. Environmental conditions Ambient temperature: -30℃~55℃ Relative humidity: 5%~95%

 Medium temperature: -30℃~80℃ Atmospheric pressure: 96Kpa~10Kpa

2. Fluid conditions: the fluid to be measured should be a single-phase gas, and the flow rate and pressure range of the fluid to be measured should be within the specified range