Wiring method of explosion-proof electric contact pressure gauge

Aug 14, 2026

explosion proof pressure gauge 09 Explosion Proof YX-160B Explosion-proof Electric Contact Pressure Gauge With Switch Controller

The wiring method of explosion-proof electric contact pressure gauge mainly includes the following steps:

Preparation before installation: Before installing the explosion-proof electric contact pressure gauge, you should carefully check the model, specifications and accuracy level of the instrument to ensure that they meet the requirements for instrument use. At the same time, check whether the connector thread of the instrument is consistent with the installed female thread.

Vertical installation: The explosion-proof electric contact pressure gauge should be installed vertically, with an inclination generally not greater than 30°, and strive to maintain the same horizontal position as the measurement point to avoid indication errors.

Check the zero position: After installation, without pressure, observe whether the pointer is at the zero position or close to the plate stopper, otherwise it should not be used.

Special requirements for measuring steam pressure: If steam pressure needs to be measured, an annular tube should be installed at the lower end of the pressure gauge, and water should be used to transmit the steam pressure during use to prevent high-temperature steam from rushing into the spring tube, affecting the accuracy of the instrument, or inadvertently melting the solder, causing the instrument to leak, causing accidents or scalding people.

Open the valve slowly: When using, open the valve slowly so that the pressure slowly rises to the working position. If the valve is suddenly opened, if the pressure is out of control and exceeds the upper limit of measurement, the spring tube will be damaged, deformed, or the fan teeth will be dislodged, causing the instrument to lose its function.

Handling after use: After use, the pressure should be released slowly, and the pointer should not be suddenly dropped to zero, otherwise the pointer will hit the plate stop nail and bend or even break the pointer.

Regular calibration or maintenance: Instruments must be calibrated or maintained according to specified requirements.

Storage: The disassembled instrument should be stored in a dust-proof, dry, and non-corrosive environment.

The above is the wiring method of explosion-proof electric contact pressure gauge. These steps are crucial to ensure the normal operation of the pressure gauge and extend its service life. If you encounter any problems during wiring or use, it is recommended to contact professional technicians in time for processing.