WZPK2-336 Double Armored Thermistor
![]() |
![]() |
WZPK2-336 armored thermal resistor is a temperature sensor with a smaller diameter, easier bending, and better seismic resistance than assembled platinum resistors. It is suitable for installation in situations where assembled platinum resistors cannot be installed. The WZPK series armored platinum resistors produced by our factory use imported platinum resistance temperature measuring components, which have the advantages of precision, sensitivity, fast thermal response time, stable quality, and long service life. The outer protective sleeve of the armored platinum resistor is made of stainless steel and filled with high-density oxide insulator. Therefore, it has strong anti pollution performance and excellent mechanical strength, making it suitable for installation in harsh environments. Armored platinum resistors can be used to measure temperatures within the range of -200 to 500 ℃ and can be directly connected to secondary instruments using copper wires. Due to its excellent electrical output characteristics, it can provide accurate temperature change input signals for displays, recorders, regulators, scanners, data recorders, and computers, and should comply with the JB/T8622-1997 standard.
简易端子
|
型号 |
分度号 |
测温范围℃ |
精度等级 |
热响应时间T0.5S |
直径mm |
长度Lmm |
安装固定装置 |
|
WZPK-103S |
Pt100 |
-200~500 |
A级 或 B级 |
≤3 |
¢3 |
单支长度 100 150 200 250 300 400 500 750 1000 双支长度 100 150 200 250 300 400 500 |
无固定装置 |
|
WZPK-104S |
≤5 |
¢4 |
|||||
|
WZPK-105S |
≤8 |
¢5 |
|||||
|
WZPK-106S |
≤12 |
¢6 |
|||||
|
WZPK2-105SA |
≤8 |
¢5 |
|||||
|
WZPK2-106SA |
≤12 |
¢6 |
|||||
|
WZPK-203S |
≤3 |
¢3 |
固定卡套螺栓 |
||||
|
WZPK-204S |
≤5 |
¢4 |
|||||
|
WZPK-205S |
≤8 |
¢5 |
|||||
|
WZPK-206S |
≤12 |
¢6 |
|||||
|
WZPK2-205SA |
≤8 |
¢5 |
|||||
|
WZPK2-206SA |
≤12 |
¢6 |
|||||
|
WZPK-303S |
≤3 |
¢3 |
可动卡套螺栓 |
||||
|
WZPK-304S |
≤5 |
¢4 |
|||||
|
WZPK-305S |
≤8 |
¢5 |
|||||
|
WZPK-306S |
≤12 |
¢6 |
|||||
|
WZPK2-305SA |
≤8 |
¢5 |
|||||
|
WZPK2-306SA |
≤12 |
¢6 |
|||||
|
WZPK-403S |
≤3 |
¢3 |
固定卡套法兰 |
||||
|
WZPK-404S |
≤5 |
¢4 |
|||||
|
WZPK-405S |
≤8 |
¢5 |
|||||
|
WZPK-406S |
≤12 |
¢6 |
|||||
|
WZPK2-405SA |
≤8 |
¢5 |
|||||
|
WZPK2-406SA |
≤12 |
¢6 |
|||||
|
WZPK-503S |
≤3 |
¢3 |
可动卡套法兰 |
||||
|
WZPK-504S |
≤5 |
¢4 |
|||||
|
WZPK-505S |
≤8 |
¢5 |
|||||
|
WZPK-506S |
≤12 |
¢6 |
|||||
|
WZPK2-505SA |
≤8 |
¢5 |
|||||
|
WZPK2-506SA |
≤12 |
¢6 |
注:1)保护管材料和固定装置材料:1Cr18Ni9Ti不锈钢。
2)双支为三线制引线
*防溅式接线盒
|
型号 |
分度号 |
测温范围℃ |
精度等级 |
热响应时间T0.5S |
直径mm |
长度Lmm |
安装固定装置 |
|
WZPK-123S |
Pt100 |
-200~500 |
A级 或 B级 |
≤3 |
¢3 |
单支长度 100 150 200 250 300 400 500 750 1000 双支长度 100 150 200 250 300 400 500 |
无固定装置 |
|
WZPK-124S |
≤5 |
¢4 |
|||||
|
WZPK-125S |
≤8 |
¢5 |
|||||
|
WZPK-126S |
≤12 |
¢6 |
|||||
|
WZPK2-125SA |
≤8 |
¢5 |
|||||
|
WZPK2-126SA |
≤12 |
¢6 |
|||||
|
WZPK-223S |
≤3 |
¢3 |
固定卡套螺栓 |
||||
|
WZPK-224S |
≤5 |
¢4 |
|||||
|
WZPK-225S |
≤8 |
¢5 |
|||||
|
WZPK-226S |
≤12 |
¢6 |
|||||
|
WZPK2-225SA |
≤8 |
¢5 |
|||||
|
WZPK2-226SA |
≤12 |
¢6 |
|||||
|
WZPK-323S |
≤3 |
¢3 |
可动卡套螺栓 |
||||
|
WZPK-324S |
≤5 |
¢4 |
|||||
|
WZPK-325S |
≤8 |
¢5 |
|||||
|
WZPK-326S |
≤12 |
¢6 |
|||||
|
WZPK2-325SA |
≤8 |
¢5 |
|||||
|
WZPK2326SA |
≤12 |
¢6 |
|||||
|
WZPK-423S |
≤3 |
¢3 |
固定卡套法兰 |
||||
|
WZPK-424S |
≤5 |
¢4 |
|||||
|
WZPK-425S |
≤8 |
¢5 |
|||||
|
WZPK-426S |
≤12 |
¢6 |
|||||
|
WZPK2-425SA |
≤8 |
¢5 |
|||||
|
WZPK2-426SA |
≤12 |
¢6 |
|||||
|
WZPK-523S |
≤3 |
¢3 |
可动卡套法兰 |
||||
|
WZPK-524S |
≤5 |
¢4 |
|||||
|
WZPK-525S |
≤8 |
¢5 |
|||||
|
WZPK-526S |
≤12 |
¢6 |
|||||
|
WZPK2-525SA |
≤8 |
¢5 |
|||||
|
WZPK2-526SA |
≤12 |
¢6 |
注:1)保护管材料和固定装置材料:1Cr18Ni9Ti不锈钢。
2)双支为三线制引线