Metal rotor flowmeter, also known as variable area flowmeter, has the characteristics of simple structure, reliable operation, wide applicability, accurate measurement, and easy installation. The metal rotor flowmeter has high temperature and high pressure resistance. The ZNLZ series metal rotor flowmeter includes ordinary metal rotor flowmeter and anti-corrosion metal rotor flowmeter. The above two types are divided into on-site indication type (ZNLZZ -) and electric remote transmission type (ZNLZD -), ordinary flow sensor, instrument material (1Cr18Ni9Ti), and anti-corrosion type (1Cr18Ni9Ti) lined with PTEF.
If the medium measured by the metal rotor flowmeter contains ferromagnetic particles, a magnetic filter should be installed at the inlet of the flowmeter. Its material should be the same as the corresponding flowmeter.

Main technical parameters of metal rotor flowmeter
(1) Basic
Measurement range of metal rotor flowmeter: water (20 ℃) 2.5-150000L/h
Air (20 ℃, 0.1013MPa) 0.07-4000Nm3/h
Metal rotor flow measurement range ratio: 10:1
Precision of metal rotor flowmeter: 1.5/2.5
Working pressure of metal rotor flowmeter: ≤ 6.4MPa
Working temperature of metal rotor flowmeter: -40~350 ℃ (fluoroplastic lining -10~80 ℃)
Metal rotor flowmeter ambient temperature: -20~80 ℃
Medium viscosity of metal rotor flowmeter: DN15 ≤ 5mPa S
DN25~DN150 ≤ 250mPa S
Tube material: 1Cr18Ni9Ti, 316L, lined with PTEF, etc
Process connection: flange, or as provided by the user
Steam fitting: flange, DN15/PN1.6, or as provided by the user
(2) Remote transmission device
① ZN5W1-1 angular displacement transmitter
Basic error: 1.5% F.S
Output signal: 4-20mA
Load impedance: 350 Ω
Power supply voltage: 24VDC
Environmental temperature: -30~80 ℃
Outlet: M20 × 1.5
Explosion proof mark: ExibIICT4
② ZNE-HD transmitter
Power supply impact:<0.1% (excluding digital resolution [70 μ A)
Load impact:<0.1% (excluding digital resolution [70 μ A)
Current loss: 4~21.6mA, relative to 0% of the measured value
Load impedance: 0-800
Working voltage: 12.8-30VCD
Two wire Rext [K Ω]=(power supply [V] -12.7)/22mA
Output signal: 4-20mA
Environmental temperature: -25~80 ℃
Outlet: M20 × 1.5
Explosion proof mark: ExibIICT6
Specification of metal rotor flowmeter:
|
Diameter(mm) |
Flow range |
pressure lose kPa |
|||
|
water L/h* |
air M3/h* |
water |
air |
||
|
Conventional type |
Explosion proof type |
conventional and Explosion proof type |
|||
|
15 |
2.5~25 |
--- |
0.07~0.7 |
6.5 |
7.1 |
|
4.0~40 |
2.5~25 |
0.11~1.1 |
6.5 |
7.2 |
|
|
6.3~63 |
4.0~40 |
0.18~1.8 |
6.6 |
7.3 |
|
|
10~100 |
6.3~63 |
0.28~2.8 |
6.6 |
7.5 |
|
|
16~160 |
10~100 |
0.40~4.0 |
6.8 |
8.0 |
|
|
25~250 |
16~160 |
0.7~7.0 |
7.2 |
10.8 |
|
|
40~400 |
25~250 |
1.0~10 |
8.6 |
10.0 |
|
|
63~630 |
40~400 |
1.6~16.0 |
11.1 |
14.0 |
|
|
25 |
100~1000 |
63~630 |
3~30 |
7.0 |
7.7 |
|
160~1600 |
100~1000 |
4.5~45 |
8.0 |
8.8 |
|
|
250~2500 |
160~1600 |
7~70 |
10.8 |
12.0 |
|
|
400~4000 |
250~2500 |
11~110 |
15.8 |
19.0 |
|
|
40 |
500~5000 |
--- |
12~120 |
10.8 |
9.8 |
|
600~6000 |
---- |
16~160 |
12.6 |
16.5 |
|
|
50 |
630~6300 |
400~4000 |
18~180 |
8.1 |
8.6 |
|
1000~10000 |
630~6300 |
25~250 |
11.0 |
10.4 |
|
|
1600~16000 |
1000~10000 |
40~400 |
17.0 |
15.5 |
|
|
80 |
2500~25000 |
1600~16000 |
60~600 |
8.1 |
12.9 |
|
4000~40000 |
2500~25000 |
80~800 |
9.5 |
18.5 |
|
|
100 |
6300~63000 |
4000~40000 |
100~1000 |
15.0 |
19.2 |
|
150 |
20000~100000 |
--- |
600~3000 |
19.2 |
20.3 |