The working principle and main characteristics of metal rotor flowmeter
![]() |
![]() |
1, Working principle of metal rotor flowmeter
The float of the metal tube rotor flowmeter moves upward in the measuring tube with the change of flow rate, and at a certain position, the buoyancy and gravity of the float reach equilibrium. At this time, the circulation gap area between the float and the orifice plate (or cone tube) remains constant. The annular gap area is directly proportional to the rising height of the float, that is, the position where the float rises in the measuring tube represents the size of the flow rate. The change in the position of the float is transmitted by the internal magnet to the external indicator, so that the indicator correctly indicates the current flow rate value. This means that the indicator housing does not come into direct contact with the measuring tube, so even if limit switches or transmitters are installed, the instrument can be used under high temperature and high pressure working conditions.
2, Main characteristics and structural types of metal rotor flowmeter
All metal structure, including indicator type, electric remote transmission type, corrosion-resistant type, high-voltage type, jacket type, and explosion-proof type. It has standard analog signal output and on-site indication of 0-10mA and 4-20mA. Accumulation, digital communication, on-site modification of measurement parameters, different power supply functions, with magnetic filters and special specifications. Widely used in industries such as petroleum, chemical, power generation, pharmaceuticals, food, water treatment, etc. During the flow measurement process under complex, harsh environmental conditions, and various media conditions.
When measuring gas media
When used for gas measurement, it should be ensured that the pipeline pressure is not less than 5 times the pressure loss of the flowmeter to ensure stable operation of the float; If the gas is directly discharged into the atmosphere at the outlet of the flowmeter, a valve should be installed at the outlet of the instrument, otherwise a pressure drop will occur at the float, causing data distortion.