What is the reason for the connection screw falling off
In this case, the pressure gauge looks normal from the outside, but when the pressure is applied to the gauge, even if the pressure reaches the upper limit of measurement, the pressure gauge pointer does not move. If you pick up the watch and shake the stainless steel pressure gauge, you can hear the sliding sound of parts inside the watch case. If the cover is disassembled, it is found that the connecting screw between the connecting rod and the sealing plate has fallen off, or the connecting screw between the connecting rod and the sector teeth has fallen off.
After the recurrence of this kind of situation, the meter will lose its most basic use function, and thermal resistance users will not accept it.
The main reason for the falling off of the connecting screw should be relatively simple to analyze. The main reason is that after the instrument is adjusted, the screw at the end of the sealing sheet or the end of the segment is not tightened, so that the stainless steel pressure gauge is repeatedly pressurized during the use of the instrument. When the pressure is relieved, especially in the case of large vibration in the working environment, the thermal resistance will cause the connection thread to fall off.