Dial Remote Reading Thermometer with Capillary Tube

If the capillary remote thermometer needs to be made longer, such as 2M, it can be customized. If it needs to be made shorter, such as 70mm, the order should indicate the length below or including the thread. Generally speaking, the length below the thread

capillary thermometer 050801

Capillary thermometer with flange

capillary thermometer probe

Capillary thermometer probe 

 

Technical parameters of capillary remote thermometer:

1. Executive standard: JB/T8803-1998 GB3836-83, nominal diameter of scale plate: 60100150;

2. Accuracy level: 1.0, 1.5; Thermal response time: ≤ 40S; Protection level: IP55;

3. Angle adjustment error: The angle adjustment error should not exceed 1.0% of its range; The return error should not exceed the value of the basic error limit;

4. The repeatability limit range of the thermometer should not exceed 1/2 of the basic error limit.

Capillary remote thermometer

It is composed of bimetallic sheets that are wound into a circular curved shape. When one end is heated and expanded, it drives the pointer to rotate, and the working instrument displays the corresponding temperature value. It also prevents environmental vibration by filling the inside of the thermometer with silicone oil or separating the display part from the measurement part to achieve shockproof effect. When the temperature changes, it drives the contact to change. When it is disconnected from the upper and lower limit contacts, it causes the relay in the circuit to act, thereby automatically controlling and alarming.

Main features: on-site display of temperature, intuitive and convenient; Safe and reliable, with a long service life; Multiple structural forms can meet different requirements. Mercury free, easy to read, sturdy and shock resistant. The protective pipes are 0Cr18Ni9 1Cr18Ni9Ti stainless steel and molybdenum titanium, with strong pressure and corrosion resistance, and can be maintained or replaced for a short time without stopping the machine.

The dial and probe are presented at 135 degrees, and the dial and probe of the universal bimetallic thermometer can be freely adjusted. Users can choose the form according to their on-site situation, and the length of the probe is usually 80mm or 100m. If it needs to be made longer, such as 2M, it can be customized. If it needs to be made shorter, such as 70mm, the order should indicate the length below or including the thread. Generally speaking, it is the length below the thread. The commonly used temperature ranges include -80-+40 ℃, -40-+80 ℃, 0-50 ℃, 0-100 ℃, 0-150 ℃, 0-200 ℃, 0-300 ℃, 0-400 ℃, 0-500 ℃, etc. For example, if the user measures a temperature of 50 ℃, it is better to choose 0-100 ℃ or 0-150 ℃. When the high temperature of Zui is 50 ℃, we usually choose a temperature range higher than the actual thermometer to prevent unexpected situations that may cause damage to the instrument. The correct temperature range is the foundation of service life and accuracy.

 